intracorneal
1
1
Intra-stormal implants are called Rings, Segments or ICRs and were designed and developed to be used
as a correction for reducing or eliminating myopia of minus 0.5 to minus 8.0 diopters.
They are also used for the correction of keratoconus if properly implanted into the stroma of the cornea,
outside of the optic zone.
Products  Foldable intraocular lens  PMMA iols  Viscoelastics  Phacoemulsification system  Intra-stromal inlays  CTRs  Sutures  Instruments  Sterilizers  Economy  Links  Search
KERATACxPLUS™, THE FIRST FOLDABLE INTRACORNEAL RINGS FOR OPHTHALMIC SURGERY
Eye4Vision Int'l.
email
ovd
ICR
CTR
pmma
products
phaco system
instruments
sterilizers
links
search
sutures
Home
economy
intra-corneal
Intra-stromal Inlays
TOP
KERATACxPLUS™
NOW AVAILABLE
Elastic in Nature
About us  Cataract Surgery Packs  VISION2020  Donate here  Cold Phaco  Projects  Ophthalmic microscopes  Cataract kit  Sitemap
Intracorneal rings


KERATACxPLUS™, the First foldable intracorneal rings for ophthalmic surgery
®
'Elastic in Nature'




KERATACxPLUS™ made from Advanced Polymer hydrophilic acrylic material
KERATACxPLUS™, world's first foldable, soft intracorneal inlay
Available segments in varying sizes: 45°, 90°, 160° and 320°
KERATACxPLUS™ offers a 'Kinder and Gentler' solution for keratoconus
KERATACxPLUS™ Intra-stromal inlays

LAUNCHED
foldables
1
Advanced Polymer
Advanced Polymer
KERATACxPLUS™ is manufactured from Advanced Polymer material UV 2-HEMA EOMEA,
a 25% water content Hydrophilic Acrylic material suited for implantable ophthalmic applications.
The polymer is a 100% Acrylic with excellent mechanical and optical properties.
KERATACxPLUS™, foldable hydrophilic acrylic intra-stromal inlays or intracorneal rings
will be launched soon. Check this website regularly!
made in usa
Introduction
Corneal Inlays
KERATACx™
Intra-stromal
Inlays
KERATACx
PLUS™
Foldable
Intra-stromal
Inlays
introduction
corneal inlays
corneal inlays
SIZE

150µ
200µ
250µ
300µ
350µ
400µ
450µ
500µ
NOMINAL
CORRECTION
0.25
0.8
1.5
2.2
2.9
3.6
4.2
4.9
RANGE

< 0.5D
0.6 - 1.0 D
1.3 - 1.7 D
2.0 - 2.4 D
2.7 -3.1 D
3.4 - 3.8 D
4.0 - 4.4 D
4.7 - 5.1 D
KERATACx™ NOMOGRAM
Note:
The chart above is only a guideline and Surgeons must use
their own experience and expertise.
Calculating Diopter:
Determining the implant needed for the proper correction of the patient’s myopia will depend on each surgeon’s
specific implantation technique. Surgeons should use their own calculation and experience for product selection
remembering that the optical zone ( Diameter ) of Keratacx is 6.2mm as opposed to INTACS™ 6.8mm.
Therefore, Keratacx will tend to make a slightly higher correction.
1
Calculation